| The following commands are
done on MONTY
Stopping a tape (e.g.
on maintenance days):
> JOB
> TAPE FIN SHUT
Stop a tape a switch to
the other tape:
> JOB
> TAPE FIN SWI
To start a tape and turn
on switch mode:
To use the help function
on Monty, enter command as follows:
> TAPE HELP
or
> TAPE HELP command (where
command is the command you want to see the syntax for)
If you need to stop a
tape when Monty is down or there is a correlator problem not allowing Monty
to function normally:
On Monty:
> JOB
> TAPE STOP
On Boss:
ctrl + a
//WEO TPF (tpf is the currently
used tape)
ctrl + a
//WEO TPF
(this put a double end-of-file
on the tape)
//R
VISIBILITY TAPE ARCHIVING
When a 9-track tape is full,
it will automatically rewind. A message will come up on the BOSS console
in the control room giving the end time of the tape. This time is recorded
in the current observing log (hit yellow bart button to get dialog box
for Visibility Tape info).
When tape is finished rewinding,
remove tape from unit and take off write ring.
Insert 9-track tape in 9-track
machine.
Put appropriately numbered
DAT tape in DAT machine (same number as 9-track tape).
From a Banshee window type
> duplicate
This process will take about
15 minutes. Tape will automatically eject when completed.
Clean tape unit that tape
was removed from: clean heads with alcohol on swab; clean tape path and
glass panels with towelette.
Load new tape: put tape
on spindle, push spindle down to lock, close tape unit door; hit buttons
RESET, LOAD/REWIND, ONLINE (in that order).
Make sure that tape loads
correctly!
When the tape has finished
duplication, the newly copied data on the DAT tape must be checked.
To do this, open the OPSED
window and type
> OPTAPE tape=##### (where
##### is the number of the tape that was duplicated)
(or type ctrl+p to get last
entry and change number)
When the tape checking operation
is finished (about 15 minutes), the DAT tape will automatically eject,
and a report will print out on the small printer in the operator's area.
This report will give the start and finish time of the tape. These times
are put on both the label on the original 9-track tape and on the insert
of the DAT tape.
The report and the DAT tape
are taken to the AOC at the end of your shift. The 9-track tape is hung
in the appropriate place in the tape rack.
MONITOR DATA TAPE HANDLING:
Only put 7 files on a tape
Use tapes ending in 0
To copy files:
Load tape on MT1; follow
instructions on sheet at terminal |