| Modcal
Use the file SYSFLUX
*** The source must be above
45° to run this process! ***
Source on line #12 is the
pointing source (file starts on this source)
Wait for 2 or 3 pointing
scans to complete
Continue to next source,
do a SKIP 1 1
When all antennas are on
source and fringing (take out any problem antennas now), run Modcal program:
With mouse cursor in XTERM
window running F display type the letter M
This action will generate
the printout
The printout gives a table
of values. Mark values falling outside of 0.8 - 1.2 ± 0.20
Check this list against
the Antenna Status Report |